Abstract
Fluid therapy is a vital clinical procedure used to treat circulatory shock. Approx imately 30% of patients in the ICU undergo fluid therapy at some point during their stay, rising to 50-80% in some specialised units. It affects ≈ 1 million patients per year in the EU, with similar proportions in the developed world. Fluid ther apy aims to maintain, or increase, cardiac output by increasing the total volume in cardiovascular system, thereby maintaining sufficient organ perfusion. Currently, it is estimated only 50% of patients receiving fluid therapy experience an increase in cardiac output. Furthermore, patients who receive unnecessary fluids are prone to fluid overload, which has been linked to increased requirement of mechanical ventilation, increased length of hospital stay, and increased mortality. Thus, to maximise benefit and minimise unintended harm, it is crucial to have a firm understanding of a patient’s fluid responsiveness prior to administering fluids. A patient is considered fluid responsive if they have a low preload, defined as the stretch in the cardiac wall before cardiac contraction occurs. However, since direct measurements of preload are not possible due to their highly invasive and risky nature, indices indicative of low preload are used instead. These indices are categorised into two separate types, static and dynamic. Static indices have been found to be poor predictors of fluid responsiveness. De spite their poor performance, they are still widely used to guide fluid therapies in many hospitals globally, primarily due to their simplicity. Dynamic indices are defined based on cardiopulmonary interactions experienced during mechanical ventilation. They have been shown to be a better indicator of fluid responsiveness than static indices. However, they are highly limited in many different clinical scenarios, such as spontaneous breathing, open thorax or arrhythmias, and harder to obtain readily. Mechanical ventilation is a critical support for many patients in ICU, and virtually all patients with cardiac shock or needing fluid therapy are ventilated. However, it is well known for having detrimental effects on cardiovascular system performance, particularly when using high positive end-expiratory pressure. High positive end expiratory pressure levels cause a decrease in stroke volume, which, under normal conditions, usually brings about a decrease in stressed blood volume and perfusion. The result is two necessary therapies, mechanical ventilation and fluid therapy, act in a contrasting or antagonistic fashion. Stressed blood volume (SBV) is defined as the total pressure-generating blood volume in the circulation and describes the volume contributing to tissue perfusion. It has recently been validated as a potential index of fluid responsiveness by multi ple studies. However, clinically determining the stressed blood volume of a patient is a highly complex and dangerous procedure, involving multiple cardiac arrests and fluid infusions, and is clearly not a clinically viable diagnostic or monitoring procedure. Therefore, accurate model-based or other surrogates are required if SBV is to be used as an index of fluid responsiveness in regular monitoring. Model-based tools are being increasingly explored for bedside diagnostics. There is currently a large movement towards the so-called “digital twin”, a digital version of a patient which can be used to simulate treatment therapies and provide predic tions for patient outcome. Being able to predict a patient’s response to treatment therapies has the potential to greatly reduce cost, length of stay, and ultimately mortality. Generally, respiratory and haemodynamic care are provided independently of one another. However, since positive end-expiratory pressure alters both stroke volume and stressed blood volume suggests both the pulmonary and cardiovascular state should be conjointly optimised and used to guide positive end-expiratory pres sure. However, the complex and patient-specific nature of the cardiopulmonary interactions which occur during mechanical ventilation presents a challenge for ac curate modelling of respiratory and cardiovascular interactions required to better optimise care. Furthermore, for model-based methods to be implemented in the ICU, they require access to a patient’s clinically available data. The currently used bedside care systems are bedside monitoring devices, which provide real-time visual information to bedside nurses and clinicians. While providing a crucial service to bedside care, these proprietary devices act as a large obstruction to advancements in model based care, as they do not provide access to real-time patient information and keep information locked away behind large cost barriers. This work explores multiple cardiovascular and combined cardio-pulmonary mod els, to evaluate their ability to reliably identify haemodynamics parameters, and crucially, stressed blood volume. A newly created data capture system is designed to obtain haemodynamic measurements in a clinical setting. The device is used for a trial at University of Liege hospital (CHU de Liege) to capture haemodynamic measurements from patients undergoing fluid therapy. The data obtained from the trial is then used in a real-time simulation for identification of stressed blood volume. Finally, a validation of the real-time identified stressed blood volume as an index of fluid responsiveness is performed. All of the 3 models, the 3 chamber model and two cardiopulmonary models, were simulated using experimental porcine data obtained from experiments performed at the University of Liege. The 3 chamber model ultimately proved to be more reliable than the cardiopulmonary models, particularly during higher PEEP. A clinically feasible 3 chamber model was validated on the same porcine data, using an arterial transfer function to identify aortic pressure from femoral pressure. The clinically feasible model was able to reliably identify SBV from a clinically available measurement set. The data capture system was trialled successfully at CHU de Liege, and captured arterial and venous pressure, as well as fluid infusion rates from 3 patients during a fluid infusion. This data was then used to perform a real-time simulation, where the retrospective data was streamed over serial in real-time to a MATLAB application which split the data into beats and was able to identify SBV on a beat-to-beat basis in real-time. Finally, the real-time SBV was validated as an indicator of fluid responsiveness, ultimately performing the first ever validation of real-time identified SBV from a clinically obtained dataset.