Imaging Microtubule Dynamics In Vivo in Human Brain: Optimal Quantification Based on a TestRetest Study

Read full text
Authors: Francesca Zanderigo, Gjertrud Louise Laurell, Mikhail Doubrovin, Andrei Molotkov, Alessandra Alì, Rodolfo Arevalo, Kiran Kumar Solingapuram Sai, J. John Mann, Akiva Mintz
Cited by: 0
References: 30

Abstract

Microtubules are cytoskeletal components that play essential roles in the brain, including supporting neuronal structure, protein transport, and cognitive function. In vivo quantification of microtubule dynamics using PET is possible with 11C-MPC6827, a brain-penetrant radiotracer that has been evaluated in mice and nonhuman primates. Here we present the first assessment of 11C-MPC6827 test–retest properties in a healthy human brain and examine the influence of scan duration on repeatability. Methods: Five healthy volunteers underwent two 90-min 11C-MPC6827 PET scans with concurrent arterial blood sampling (4 imaged twice in 1 d, 1 rescanned after 1 y). Radiotracer time–activity curves were extracted from 46 individual brain regions, in addition to the whole brain. Total distribution volume (VT) was estimated using kinetic models and graphical analysis. SUVs and the SUV ratio to whole brain (SUVRWB) were computed in 2 postinjection time windows. Repeatability was assessed using absolute test–retest percent difference (TRPD) and intraclass correlation coefficient (ICC). Time stability was examined by truncating imaging data from 90-min to 60-min acquisition and comparing computed outcomes to the 90-min value as gold standard. Results:VT estimates were stable with truncated scan time (average shorter VT/90-min VT, 1.003–1.030). For the same-day test–retest pairs, VT estimates obtained with kinetic models showed average TRPD values, across regions and participants, between 10.18% and 14.26%, and ICCs between 0.483 and 0.966. Graphical approaches demonstrated lower repeatability than kinetic models. Across methods, TRPDs were lower and ICCs were higher with shorter scans. SUV showed higher interscan variability in TRPD. SUVRWB was more stable (TRPD, 2.22%–5.47%) and less influenced by scan duration. However, ICCs were overall much lower for SUV and SUVRWB than for VT. Conclusion:11C-MPC6827 shows good repeatability for quantifying microtubule dynamics in humans using arterial blood even at a 60-min scan duration. SUVRWB could be a convenient blood-free alternative to VT.

Fields of Study & Subjects

Medical Imaging Techniques and Applications Radiopharmaceutical Chemistry and Applications Alzheimer's disease research and treatments

Publication details

Journal / source
Journal of Nuclear Medicine
Volume
67
Issue
4
Pages
644–650
Publication date
12 February 2026
Language
EN