SEMI-ACTIVE CONTROL DESIGN OF HIGH-RISE SEISMIC ISOLATED BUILDING USING A SINGLE-MASS MODEL WITH TIME-VARYING DAMPING SWITCHING CONDITION APPLIED TO PREDOMINANT FREQUENCY OF EARTHQUAKE MOTION

Read full text Summarise with VIRAT
Authors: Daichi Hatano, Nanako Miura
Cited by: 0
References: 26

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Semi-active control by optimal control of two-stage variable damper determines variable damping by comparing the optimal control force obtained from structural response feedback with a threshold called damping switching condition. This study proposes a methods for varying the damping switching condition based on predominant frequency of earthquake motion. In designing the control, assuming the seismic isolated building is rigid and using a single-mass model allows design to consider only the primary natural mode. Applying the control designed using a single-mass model to a multi-mass model demonstrated superior control performance compared to conventional methods using a fixed damping switching condition.

Fields of Study & Subjects

Vibration Control and Rheological Fluids Seismic Performance and Analysis Seismic and Structural Analysis of Tall Buildings

Publication details

Journal / source
Journal of Structural and Construction Engineering (Transactions of AIJ)
Volume
91
Issue
842
Pages
450–460
Publication date
31 March 2026
Language
EN