STRENGTH OF INSERTS FOR BUILDING EQUIPMENT EMBEDDED IN CONCRETE SLABS

Read full text Summarise with VIRAT
Authors: Ichiro Hirano, Shoichi Kishiki
Cited by: 0
References: 3

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Recent earthquakes have caused damage to inserts, which connect hanging bolts for suspended equipment such as air conditioners to concrete slabs. To ensure their seismic performance, it is necessary to evaluate the strength of inserts under combined tensile and shear forces. In this study, loading tests were conducted on various types of inserts embedded in concrete slabs, considering differences in surrounding concrete geometry and loading conditions. Based on the test results, the structural behavior of inserts under combined loading was clarified, and an evaluation method for allowable strength was proposed to prevent yielding, fracture, and cone failure.

Fields of Study & Subjects

Structural Behavior of Reinforced Concrete Seismic Performance and Analysis Construction Engineering and Safety

Publication details

Journal / source
Journal of Structural and Construction Engineering (Transactions of AIJ)
Volume
91
Issue
842
Pages
554–565
Publication date
31 March 2026
Language
EN