The Feasibility, Accuracy and Safety of Robot-Assisted Ventriculoperitoneal Shunt
Abstract
OBJECTIVE: Ventriculoperitoneal shunt (VPS) treats hydrocephalus effectively, but manual ventricular catheter placement has a high misplacement rate. This study assesses the feasibility, accuracy, and safety of robot-assisted VPS. METHODS: A retrospective analysis was performed on the clinical data of 87 patients from 2022 to 2024, with 42 receiving robot-assisted VPS and 45 receiving conventional manual VPS. Logistic regression analysis was performed to identify risk factors affecting placement accuracy. RESULTS: The robot-assisted cohort showed smaller bilateral frontal horn diameters and a lower Evans index (p
Fields of Study & Subjects
Cerebrospinal fluid and hydrocephalus
Neurosurgical Procedures and Complications
Pleural and Pulmonary Diseases
Publication details
- Journal / source
- Journal of Korean Neurosurgical Society
- Volume
- 69
- Issue
- 3
- Pages
- 459–471
- Publication date
- 13 February 2026
- Language
- EN