Comparison of Bruker Biotyper Sirius, VITEK MS PRIME, and ASTA MicroIDSys MALDI-TOF MS Systems for Cryptococcus Species Identification Across Protein Extraction Protocols

Read full text Summarise with VIRAT
Authors: Bosung Park, Eunsang Suh, Eun Jeong Won, Tae Yeul Kim, Hee Jae Huh, Heungsup Sung, Mi-Na Kim
Cited by: 0
References: 35

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Background: Accurate and rapid identification of Cryptococcus spp. is critical for patient care. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is increasingly used for yeast identification; however, its performance varies with instrument and database coverage. We compared the performance of three MALDI-TOF MS systems—Bruker Biotyper Sirius (Sirius; Bruker Daltonics), bioMérieux VITEK MS PRIME (PRIME; bioMérieux), and ASTA MicroIDSys (ASTA; ASTA Inc.)—for detecting Cryptococcus spp. across protein-extraction protocols. Methods: We analyzed 51 C. neoformans , two C. deuterogattii , five Vanrija humicola , and one Naganishia liquefaciens clinical isolates. Each isolate was tested after on-plate formic acid extraction; isolates failing identification were retested after repeat on-plate and intube extractions. The results were categorized as correct, incomplete, incorrect, or no identification against ribosomal DNA sequencing results. Results: After initial on-plate extraction, correct identification rates were 86.4%, 88.1%, and 69.5% for Sirius, PRIME, and ASTA, respectively. After repeat on-plate extraction, ASTA accuracy increased to 81.4% ( P =0.016). Additional in-tube extraction did not significantly improve identification across platforms, although PRIME outperformed ASTA ( P =0.012). All platforms reliably classified C. neoformans (correct identification rates: 94%–96%) after additional on-plate extraction; discrepancies occurred mainly in uncommon species, possibly owing to gaps in database coverage. Conclusions: Sirius and PRIME demonstrated robust performance for C. neoformans identification and C. gattii complex differentiation, outperforming ASTA for relatively rare species. Single on-plate extraction is sufficient in clinical practice. However, continued database expansion is essential for maximizing MALDI-TOF MS performance and accurately identifying Cryptococcus spp., thereby informing antifungal therapy and improving patient outcomes.

Fields of Study & Subjects

Bacterial Identification and Susceptibility Testing Fungal Infections and Studies Mass Spectrometry Techniques and Applications

Publication details

Journal / source
Annals of Laboratory Medicine
Volume
46
Issue
6
Pages
711–720
Publication date
2 April 2026
Language
EN