Clinical morphology and anterior segment optical coherence tomography analysis of trabeculectomy blebs

Read full text Summarise with VIRAT
Authors: Suraj Bhagde, Ketki Purecha, Manjula Ballamudi, Vishakha Patil, Monisha Jaiswal
Cited by: 0
References: 18

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Background: Trabeculectomy is the preferred surgery for glaucoma, but its success depends on the filtering bleb. Slit-lamp biomicroscopy, the standard tool for bleb evaluation, is limited to external features. In contrast, Anterior Segment - Optical Coherence Tomography (AS-OCT) offers a detailed internal assessment of the bleb. This study examines the correlation between slit-lamp findings and AS-OCT imaging to assess trabeculectomy success. Methods and Materials: This single-center, prospective observational study included 68 eyes from 68 glaucoma patients undergoing trabeculectomy. Postoperative bleb morphology was assessed using slit-lamp biomicroscopy (IBAGS bleb grading) and AS-OCT at 15 days, 1 month, and 3 months. Correlation analysis examined the relationship between IOP, clinical bleb grading, and AS-OCT parameters. Results: The study included patients with a mean age of 63.09±9.56 years and an equitable gender distribution. Mean preoperative IOP was 23.29±9.29 mmHg, which decreased significantly postoperatively to 14.59±5.35 mmHg at 15 days, 14.0±4.85 mmHg at 1 month, and 13.41±3.27 mmHg at 3 months, indicating continued surgical success. A significant negative correlation was observed between IOP and bleb height, optical intensity, and bleb wall thickness on OCT. Of 42 blebs with multiform reflectivity, only 3 (7.14%) converted to uniform reflectivity, demonstrating the effectiveness of interventions in maintaining multiform reflectivity (92.86%). Conclusion: Bleb morphology assessed by IBAGS grading correlates accurately with AS-OCT parameters thereby highlighting its role in post-trabeculectomy bleb monitoring. Lower optical intensity, multiform reflectivity and good bleb wall height are indicative of functioning blebs and corresponding low IOP values.

Fields of Study & Subjects

Glaucoma and retinal disorders Corneal surgery and disorders Intraocular Surgery and Lenses

Publication details

Journal / source
International Journal of Ophthalmology Research
Volume
8
Issue
2
Pages
07–12
Publication date
1 February 2026
Language
EN