Recurrent coronary artery in-stent restenosis caused by metal allergy: a case report

Read full text
Authors: Yang Li, Zhengbang Dong, Qiming Dai, Yi Feng, Lijuan Chen, Genshan Ma
Cited by: 0
References: 19

Abstract

This article describes the case of a middle-aged woman who developed recurrent in-stent restenosis (ISR) due to metal allergy. The first ISR occurred after implantation of a nickel-rich Medtronic Endeavor Resolute stent (35% nickel, 35% cobalt, and 20% chromium). A skin patch test revealed a strong nickel allergy (++), with no allergic reaction to cobalt. Nickel allergy was considered to be the cause of the first ISR. Then, a drug-coated balloon platinum-chromium alloy stent was implanted, and ISR occurred again during follow-up. The article discusses this special case and clinically relevant management options. This case highlights a scenario with refractory in-stent restenosis persisting despite various treatment strategies, including stents with different metal components, drug-coated balloons, and intensive drug therapy.

Fields of Study & Subjects

Contact Dermatitis and Allergies Coronary Interventions and Diagnostics Cardiac pacing and defibrillation studies

Publication details

Journal / source
Frontiers in Cardiovascular Medicine
Volume
12
Pages
1693234–1693234
Publication date
9 January 2026
Language
EN