Feasibility of [15O]H2O PET-CT for quantifying lower limb muscle perfusion in peripheral arterial occlusive disease: a pilot study

Read full text
Authors: Goudje L van Leeuwen, Richte C. L. Schuurmann, Charalampos Tsoumpas, Milah. N. Baumann, Riemer H. J. A. Slart, Jean‐Paul P.M. de Vries
Cited by: 0
References: 27

Abstract

Background Assessing muscle tissue perfusion in patients with peripheral arterial occlusive disease (PAOD) is challenging, as conventional techniques such as computed tomography angiography and transcutaneous oxygen pressure (TcPO 2 ) do not capture perfusion within deeper muscle compartments, which are clinically relevant because symptoms such as claudication manifest in the muscles. [ 15 O]H 2 O positron emission tomography computed tomography (PET-CT) enables quantitative measurement of tissue blood flow but has not yet been systematically applied in PAOD. This exploratory study investigated the feasibility and reproducibility of using long axial field of view (LAFOV) [ 15 O]H 2 O PET-CT to quantify calf muscle perfusion in PAOD patients, comparing two VOI selection strategies and generating hypotheses for future studies. Methods Patients with Rutherford stage 3–6 PAOD undergoing endovascular revascularization underwent [ 15 O]H 2 O PET-CT imaging before and after treatment. Muscle perfusion (K1 in mL/100 cm 3 /min) was calculated using a 1-tissue compartment model and image-derived input functions. VOIs were defined using either full muscle contours or standardized spherical volumes. Ten legs from five scanning sessions (each including pre- and post-treatment imaging) were analyzed twice by two observers. Agreement and variability between methods and observers were assessed. Results K 1 values ranged from 1.54 to 5.22 mL/100 cm 3 /min. Both VOI methods enabled reproducible quantification of calf muscle perfusion. Intrarater intraclass correlation coefficients (ICCs) were ≥0.94 for both methods; interrater ICCs were 0.90 for spherical VOIs and 0.96 for muscle contours. Bland–Altman analysis showed no systematic bias. Muscle contours showed slightly higher reproducibility, likely due to anatomical accuracy. Conclusions [ 15 O]H 2 O LAFOV PET-CT enables robust quantification of muscle perfusion in PAOD. This method is promising for future studies on treatment response and pathophysiology in vascular disease.

Fields of Study & Subjects

Peripheral Artery Disease Management Systemic Sclerosis and Related Diseases Cerebrovascular and Carotid Artery Diseases

Publication details

Journal / source
Frontiers in Nuclear Medicine
Publisher
Frontiers Media SA
Volume
5
Pages
1672054–1672054
Publication date
2 January 2026
Language
EN