Reliability of DIERS pedogait system for evaluating spatiotemporal gait parameters in knee osteoarthritis and its association with Achilles tendon stiffness asymmetry

Read full text
Authors: Xingxing Shen, Jiahao Chen, J ian-xing Zhang, Jiaqing Tian, Sirun Cheng, Jichuan Cao, Congcong Li, Xuemeng Xu
Cited by: 0
References: 57

Abstract

Objective To assess the inter-rater and test-retest reliability of DIERS pedogait system for measuring gait parameters in patients with knee osteoarthritis (KOA), and to explore inter-limb differences in Achilles tendon (AT) properties, as well as the associations between the AT stiffness asymmetry index (Asy Stiffness (AT)) and gait abnormalities, visual analog scale (VAS) scores, and Kellgren-Lawrence (K/L) grades. Methods A total of 36 patients with KOA (19 unilateral, 17 bilateral) were enrolled. Two independent assessors used DIERS pedogait system to measure gait parameters, with retesting by the first assessor 1 week later. Inter-rater and test-retest reliability were quantified using intraclass correlation coefficients (ICC), while absolute reliability was assessed using standard error of measurement (SEM), minimum detectable change (MDC), and Bland-Altman analysis. Bilateral AT muscle tone and stiffness were evaluated using the MyotonPRO. Spearman correlation and multiple linear regression analyses were performed to explore the associations of AsyStiffness (AT) with both clinical variables and gait parameters. Result DIERS pedogait system exhibited excellent inter-rater (ICC: 0.900–0.987) and test-retest reliability (ICC: 0.927–0.988). Inter-rater SEM and MDC ranged from 0.07 to 44.26 and 0.20 to 122.68, respectively, while test-retest SEM and MDC ranged from 0.05 to 39.59 and 0.13 to 109.74. Bland-Altman analysis revealed no significant systematic bias. In addition, AT muscle tone and stiffness were significantly higher in the relatively severe leg (RSL) compared with the moderate leg (RML) ( P < 0.05). Asy Stiffness (AT) was positively correlated with stance phase symmetry index ( ρ = 0.514, P = 0.001), stride time ( ρ = 0.381, P = 0.022), VAS score ( ρ = 0.373, P = 0.025), and K/L grade ( ρ = 0.542, P = 0.001), and negatively correlated with gait speed ( ρ = −0.374, P = 0.025). Multiple linear regression identified stance phase symmetry index ( β′ = 0.298, P = 0.043), K/L grade 2 ( β′ = 0.533, P = 0.017) and K/L grade 3 ( β′ = 0.778, P = 0.002) as independent factors associated with Asy Stiffness (AT). Conclusion DIERS pedogait system is a reliable and objective tool for assessing gait in KOA patients. AT stiffness asymmetry is associated with gait abnormalities, pain, and KOA severity. These findings suggest that early-mid interventions targeting gait abnormalities and mitigating Achilles tendon stiffness asymmetry may provide novel prophylactic and therapeutic strategies for KOA.

Fields of Study & Subjects

Lower Extremity Biomechanics and Pathologies Musculoskeletal pain and rehabilitation Balance Gait and Falls Prevention

Publication details

Journal / source
Frontiers in Physiology
Volume
17
Pages
1780014–1780014
Publication date
11 February 2026
Language
EN