MRI approach to the patient with suspected dementia: artificial intelligence techniques and semi-quantitative rating scales compared

Read full text
Authors: Sonia Francesca Calloni, A. Diena, G. M. Agazzi, Matteo Zavarella, Paolo Quintiliano Vezzulli, Giordano Cecchetti, Edoardo Gioele Spinelli, Giulia Rugarli, Alma Ghirelli, Giuseppe Magnani, Francesca Caso, Almar von Loon
+3 more Federica Agosta, Massimo Filippi, A. Falini
Cited by: 0
References: 26

Abstract

Objectives To assess the reliability of semi-quantitative and AI-based quantitative brain volume evaluation (Quantib® ND) in predicting clinical diagnosis in patients with suspected neurodegenerative diseases undergoing initial 1.5 T MRI. Additionally, to analyze the frequency of lobar microbleeds (MBs) at diagnosis. Methods Two neuroradiologists (2 vs. 10 years’ experience), blinded to diagnosis, independently evaluated brain atrophy on 3D-T1 images of 133 subjects using Scheltens, Koedam, and Kipps scales. Automated volumetric analysis was performed using Quantib® ND. SWI images were assessed by one neuroradiologist to classify MBs as cortical, juxtacortical, subcortical, or deep. Inter-observer agreement was measured using intraclass correlation coefficients (ICC); correlation with Quantib® ND was analyzed using Spearman's coefficient. Cohen's Kappa assessed agreement with clinical diagnosis. Results Good inter-observer agreement was observed for the MTA scale (ICC 0.86 right, 0.82 left) and Kipps scale (ICC 0.76), with moderate concordance for Koedam (ICC 0.66). Frontal and posterior temporal Kipps subregions had good concordance (ICC 0.77, 0.79), while anterior temporal showed poor agreement (ICC 0.59). Diagnostic accuracy was moderate across observers and Quantib® ND. Observer 1 showed 77% sensitivity, 51% specificity; observer 2 had 79% sensitivity, 62% specificity; Quantib® ND reached 56% sensitivity, 74% specificity. Patients exhibited significantly more lobar MBs than non-dementia patients ( χ 2 p = 0.04). Conclusions Semi-quantitative visual scales proved effective and sensitive for detecting brain atrophy, showing good concordance with automated volumetric data. While AI-based quantification demonstrated higher specificity, visual assessment remained more sensitive. Lobar MBs were more frequent in neurodegenerative cases.

Fields of Study & Subjects

Dementia and Cognitive Impairment Research Advanced MRI Techniques and Applications Radiology practices and education

Publication details

Journal / source
Frontiers in Radiology
Volume
6
Pages
1667306–1667306
Publication date
27 January 2026
Language
EN