Structural Health Monitoring of LNG Storage Tanks: A Method Based on Finite Element Seismic Response Analysis

Read full text
Authors: Ke Wei, Menghan Sun, Baitao Sun, Xiangzhao Chen
Cited by: 1
References: 33

Abstract

Existing structural health monitoring of LNG (liquefied natural gas) liquid storage tanks is strictly constrained by explosion-proof safety and engineering conditions, making it impractical to achieve full-domain coverage through dense sensor deployment. How to achieve effective coverage of structural seismic weak parts under limited measuring point conditions is the core issue for monitoring scheme optimization. This paper takes a practical large full-containment LNG storage tank project as the research object and proposes a targeted sensor deployment method based on finite element seismic response analysis: identifying structural seismic weak parts through refined finite element modeling and seismic response analysis, thereby achieving coverage of critical regions and improved monitoring efficiency under limited sensor constraints. The research approach is as follows: a finite element model of the LNG storage tank is established using ADINA software and verified through modal analysis combined with on-site ambient vibration testing, ensuring the accuracy and engineering applicability of numerical simulation. Typical seismic records including El Centro, Tangshan, and TAFT are selected, and seismic response analysis of the tank is carried out, clarifying the displacement response laws under different seismic waves and identifying the junctions of dome roof and tank wall, buttress columns and tank wall, and the upper and local areas of the tank wall as structural seismic weak parts. Based on the characteristics of these parts and on-site explosion-proof conditions, a four-measuring-point targeted monitoring sensor deployment scheme is formulated and applied in engineering. This research constructs a structural health monitoring method for LNG storage tanks featuring “structural model verification–weak part identification–monitoring scheme customization,” providing a new approach for tank monitoring under explosion-proof safety constraints and partially addressing the limitations of traditional empirical deployment methods. This study establishes a technical path covering the full cycle of routine operation, seismic response, and post-earthquake assessment, providing methodological support for the structural health monitoring of LNG storage tanks, and its core concepts can also serve as a reference for the structural health monitoring of similar large-scale thin-walled storage tanks.

Fields of Study & Subjects

Fluid Dynamics Simulations and Interactions Wind and Air Flow Studies Spacecraft and Cryogenic Technologies

Publication details

Journal / source
Applied Sciences
Publisher
MDPI AG
Volume
16
Issue
10
Pages
4614–4614
Publication date
8 May 2026
Language
EN