Enhanced YOLO26 for Thermographic Fault Detection in Underground Duct Cables

Read full text
Authors: Zhimeng Chen, Kejia Hu, Junqiang Liu, Yinkai Ji, Zhu Yi, Hualun Chen, Chao Yuan, Zhiyu Chen
Cited by: 1
References: 22

Abstract

Underground duct cables are widely used in urban power distribution systems, but their enclosed installation environment makes defect inspection difficult, labor-intensive, and potentially hazardous. Infrared thermography can capture abnormal temperature distributions caused by insulation degradation, conductor damage, sheath failure, or severe structural defects, while robot-based inspection provides a promising solution for confined duct environments. However, thermographic fault detection for underground small-diameter duct cables remains insufficiently studied, and practical deployment requires lightweight models suitable for embedded edge devices. In this study, an improved YOLO26-based thermographic fault detection framework is proposed for underground duct cable inspection. A Cable-Thermo dataset is constructed using an ANSYS 2025 R2-based thermoelectric coupling simulation, covering four defect categories: hollow-type damage, conductor burnout, sheath damage, and severe damage. To balance detection accuracy and deployment efficiency, two model variants are developed. YOLO26-Thermo-E retains the original detection scales and integrates CDA and SimSPPF modules for accuracy-prioritized diagnosis. YOLO26-Thermo-H further removes the small-scale detection branch as a deployment-oriented design choice, based on the scale distribution observed in the simulation dataset, where most fault-induced thermal anomalies appear as spatially continuous medium- or large-scale regions. This design assumption still requires further validation using real duct thermographic data. Experiments show that YOLO26-Thermo-E achieves the highest mAP50 of 99.20%. YOLO26-Thermo-H maintains a mAP50 of 99.00% while reducing GFLOPs by 34.3% and parameters by 16.2% compared with YOLO26. On an NVIDIA Jetson Orin NX, YOLO26-Thermo-H reaches 34 FPS under FP16 inference and 45 FPS under INT8 inference. These results demonstrate the feasibility of the proposed framework under controlled simulation conditions and its potential for edge deployment. The limitations of the simulation-based dataset are also discussed, and future work will focus on real-scene data collection and simulation-to-real generalization.

Fields of Study & Subjects

Thermal Analysis in Power Transmission Thermography and Photoacoustic Techniques Electrical Contact Performance and Analysis

Publication details

Journal / source
Applied Sciences
Publisher
MDPI AG
Volume
16
Issue
11
Pages
5348–5348
Publication date
26 May 2026
Language
EN