Design and Pilot Evaluation of an IoT-Based Blood Pressure Monitoring System for Rabbits

Read full text Summarise with VIRAT
Authors: Carlos Exequiel Garay, Gonzalo Nicolás Mansilla, Rossana Elena Madrid, Agustina González Colombres, Susana Josefina Jerez
Cited by: 0
References: 30

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Telemedicine, driven by the Internet of Things (IoT) and wireless connectivity, is essential for managing cardiovascular diseases, where hypertension remains the primary risk factor. In preclinical research, rabbits are superior biological models compared to rodents due to their human-like lipid metabolism. However, continuous blood pressure monitoring in this species remains challenging. The gold-standard technique (direct carotid catheterization) requires terminal procedures, and indirect methods (Doppler, oscillometric) show limited agreement with direct measurements. Furthermore, commercially available implantable telemetry platforms, while enabling real-time monitoring in freely moving animals, require costly surgical implantation, specialized proprietary hardware, and post-operative recovery periods that may confound early hemodynamic data. To address these limitations, this study presents a low-cost, customizable, and minimally invasive monitoring system utilizing a pressure transducer in the central auricular artery. The device integrates an ESP32 microcontroller with IoT technology for digital signal processing and seamless wireless data transmission to the ThingSpeak cloud platform. Unlike implantable telemetry, the proposed approach avoids surgical implantation and its associated costs and recovery time, while still enabling continuous, real-time hemodynamic tracking throughout the experimental period. A pilot evaluation against the BIOPAC MP100 reference (carotid artery) demonstrated relative errors of 1.60% for mean arterial pressure, 8.58% for systolic blood pressure, and 2.43% for diastolic blood pressure. By reducing invasiveness and enhancing remote data accessibility, this system provides a promising framework for the preclinical evaluation of antihypertensive agents and cardiovascular mechanisms, bridging the gap between edge computing and remote clinical diagnostics.

Fields of Study & Subjects

Non-Invasive Vital Sign Monitoring Blood Pressure and Hypertension Studies Hemodynamic Monitoring and Therapy

Publication details

Journal / source
Bioengineering
Volume
13
Issue
4
Pages
384–384
Publication date
26 March 2026
Language
EN