Joint Action of Wind and Temperature for a Long-Span Cable-Stayed Bridge in Plateau Canyon Regions Using SHM Data and Copula-Based Probabilistic Modeling

Read full text
Authors: J. J. Bill Liu, Zefan Liu, Zhiyuan Ma, Yagang Tong, Chendi Wang, Licheng Zhu, Yongjian Liu
Cited by: 1
References: 44

Abstract

Current bridge design codes specify combination coefficients for wind–temperature joint actions, yet few studies have addressed these for bridges in plateau canyon regions. This study investigates the joint actions and combination coefficients for Haihuang Bridge, which is in a plateau canyon region surrounded by mountains. Using long-term structural health monitoring data, trivariate normal copulas and Con-KRP were applied to estimate joint probabilities of wind speed and air temperature in different directions. The combination coefficients range from 0.68 to 0.92 for temperature actions and 0.56 to 0.75 for wind actions, obtained based on the principle that bivariate Con-KRP equals univariate Con-KRP. Significant differences in the joint actions are found in different directions. Furthermore, the combination coefficients in the plateau canyon region are much larger than those in the subtropical coastal plain region, indicating a need for further study on the regional difference.

Fields of Study & Subjects

Wind and Air Flow Studies Fluid Dynamics and Vibration Analysis Structural Health Monitoring Techniques

Publication details

Journal / source
Buildings
Publisher
MDPI AG
Volume
16
Issue
5
Pages
916–916
Publication date
25 February 2026