Low-dimensional lead-free metal halide perovskites have demonstrated excellent performance in indirect X-ray detectors; however, the imaging resolution remains limited due to the lack of effective scintillation waveguiding. In this work, array-structured scintillation screens were fabricated using anodic aluminum oxide (AAO) templates via a spatial confinement–assisted in situ growth strategy. The resulting directional optical confinement effect significantly enhances the scintillation performance of the screen. The fabricated Cs3Cu2Br1.25I3.75-AAO scintillator arrays achieve a spatial resolution of 14.10 lp/mm and a minimum detectable dose rate of 243 nGy/s under X-ray irradiation. In addition, the scintillator arrays exhibit excellent radiation stability, providing a reliable and cost-effective solution for high-resolution array-based X-ray imaging.