Modelling and Simulation of a Resilient and Straightforward Energy Management System for a DC Microgrid in a Cruise Ship Firezone

Read full text
Authors: Rafika El idrissi, Robert B. Beckmann, Saikrishna Vallabhaneni, Frank Schuldt, Karsten von Maydell
Cited by: 0
References: 28

Abstract

This paper presents a practical and communication-independent energy management system (EMS) for a DC microgrid supply within the firezone of a cruise ship. The proposed approach prioritizes operational reliability and fault tolerance under emergency conditions, where communication availability and control complexity should be minimized. The proposed DC microgrid integrates photovoltaic systems (PVs), fuel cell systems (FCs), and lithium-iron-phosphate (LFP) battery energy storage systems (BESSs), coordinated through a rule-based EMS combined with droop-controlled converters. The electrical topology considered in this study is a collaborative development of the project consortium of the publicly funded project Sustainable DC Systems (SuSy), featuring a novel configuration with two independent horizontal busbars for the Cabin Area Distribution (CAD) and Technical Area Distribution (TAD). The EMS can manage two operational scenarios: (i) regular operation, with two decentralized droop controls where power generation is distributed among all generators based on their respective capacities, and a power curtailment strategy is applied to prevent overcharging of BESSs; and (ii) irregular operation, where a fault on one of the vertical busbars triggers the use of reserved battery storage capacity on both sides of the ship and activates load-shedding to ensure continued operation of critical loads and sustain grid functionality. The effectiveness of the proposed architecture is validated through detailed MATLAB/Simulink simulations. Under regular conditions, the EMS achieves stable voltage regulation, balanced power sharing, and efficient energy curtailment. During fault conditions, the battery storage on both sides successfully supports the critical loads. The fuel cells are operated in power-controlled mode effectively up to their full rated 6kW capacity while the DC bus voltage stabilization is ensured by the battery energy storage systems. These results validate the proposed EMS as a robust and low-complexity solution for maritime DC microgrids, offering stable voltage regulation, effective load prioritization, and resilient operation of critical loads.

Fields of Study & Subjects

Microgrid Control and Optimization Hybrid Renewable Energy Systems Advanced Battery Technologies Research

Publication details

Journal / source
Energies
Publisher
MDPI AG
Volume
19
Issue
11
Pages
2512–2512
Publication date
23 May 2026
Language
EN