Analysis of Chamber Wall Thickness Influence on Liquid Piston Compressor Efficiency

Read full text
Authors: Marina Koņuhova, Valērijs Bezrukovs, Valērijs Bezrukovs, Vladislavs Bezrukovs, Vladislavs Bezrukovs, M. Buryi, Anatoli I. Popov
Cited by: 2
References: 42

Abstract

Hydrogen technologies are increasingly important for energy storage and decarbonization of industrial and transport sectors. Hydrogen compression is accompanied by thermal effects that influence energy efficiency and thermal loading of compression systems. This study numerically investigates the influence of compression chamber wall thickness on heat transfer and wall temperature evolution during hydrogen compression in a liquid piston compressor. An axisymmetric multiphysics model was used to simulate a single compression stroke at initial pressures of 3–20 MPa, stroke durations of 0.5–20 s, and chamber wall thicknesses of 2.5–10 mm. The simulations show that wall temperature rise increases with compression stroke duration and initial pressure, while increasing wall thickness reduces the per-stroke temperature increase due to higher thermal inertia. The results also indicate non-uniform wall heating, with the highest temperatures occurring in the upper region of the compression chamber.

Fields of Study & Subjects

Refrigeration and Air Conditioning Technologies Thermodynamic and Exergetic Analyses of Power and Cooling Systems Advanced Thermodynamic Systems and Engines

Publication details

Journal / source
Eng—Advances in Engineering
Publisher
MDPI AG
Volume
7
Issue
4
Pages
167–167
Publication date
5 April 2026
Language