Preventive conservation of historic buildings is crucial to avoid extensive damage, yet assessments are often reactive. Following mortar detachment at the Basilica of Santa María del Pi, this paper presents a diagnosis using Non-Destructive Testing (NDT). The study employed Horizontal-to-Vertical Spectral Ratio (HVSR) for subsoil analysis and Ground Penetrating Radar (GPR) for superstructure inspection. HVSR analysis differentiated fill material from compacted ground, revealing that most of the basilica rests on infilled soil, except the northern corner, suggesting differential settlement risks. Concurrently, GPR survey of vaults and roofs identified internal structures, specifically zones lightened with hollow ceramics, and mapped high-moisture anomalies via wave amplitude and velocity analysis. The study concludes that these methods are complementary, addressing distinct spatial domains. Integrating subsoil characterization with superstructure analysis provided a comprehensive diagnosis essential for long-term maintenance and preservation.