Performance Defect Identification in Switching Power Supplies Based on Multi-Strategy-Enhanced Dung Beetle Optimizer
Abstract
To address the limited defect-detection capability of existing performance testing methods for switching power supplies under varying operating conditions, this paper proposes a defect identification approach based on an enhanced Dung Beetle Optimizer. The algorithm integrates multi-strategy improvements—including piecewise chaotic mapping, Lévy flight perturbation, hybrid sine–cosine updating, and an alert sparrow mechanism—to refine the initial population generation, position update rules, and late-stage exploration. These enhancements strengthen its spatial search ability and computational performance. The experimental results show that the method accurately identifies the predefined defect intervals with a precision of 94.79%, covering 91.3% of the operating conditions. Comparisons with existing mainstream methods confirm the superior performance, effectiveness, and feasibility of the proposed method.
Fields of Study & Subjects
Metaheuristic Optimization Algorithms Research
Photovoltaic System Optimization Techniques
Advanced DC-DC Converters
Publication details
- Journal / source
- Mathematical and Computational Applications
- Volume
- 31
- Issue
- 1
- Pages
- 12–12
- Publication date
- 12 January 2026
- Language
- EN