Fault Diagnosis of Hydro-Power Units Using BP Neural Network and XGBoost Algorithm for Enhanced Operational Safety

Read full text
Authors: Lei Kuang, Yangyang Zeng, Chao Hu, Wenjun Yao, Jiang Guo, Junjie Hu
Cited by: 0
References: 29

Abstract

To enhance operational safety and reduce maintenance costs, this study investigates the fault diagnosis of hydro-power units, where the BP neural network and XGBoost algorithm are employed. To filter environmental noise, a combination of the least squares method and dispersion analysis is utilized to filter out irrelevant and erratic operational data. Following this, the random forest algorithm is applied to rank the significance of characteristic parameters, ensuring that only the most relevant features are selected for fault diagnosis. The BP neural network, integrated with expert knowledge, is then used to extract fault characteristics, improving model accuracy. To further refine fault detection and reflect the hydro-power unit’s real-time operation, the XGBoost algorithm is employed for fault identification. A case study demonstrates the model’s ability to predict fault characteristics 16 h in advance, confirming the effectiveness and reliability of the proposed diagnostic approach.

Fields of Study & Subjects

Machine Fault Diagnosis Techniques Fault Detection and Control Systems Power Systems Fault Detection

Publication details

Journal / source
Processes
Volume
14
Issue
3
Pages
517–517
Publication date
2 February 2026
Language
EN