An Integrated UAV-Based Solution for Hyperspectral Bidirectional Reflectance Analysis: A Case Study of the Dunhuang Radiometric Calibration Site

Read full text
Authors: Haoheng Mi, Jingwei Bai, Guangyao Zhou, Hong Guan, P. F. Zhang, Hairong Tang, Kang Jiang, Yongchao Zhao
Cited by: 1
References: 44

Abstract

Angular reflectance effects are essential for radiometric calibration and the interpretation of remotely sensed data, yet remain difficult to characterize under realistic field conditions. This study presents a UAV-based approach for high-angular-resolution hyperspectral HDRF measurement over the Dunhuang Radiometric Calibration Site (DRCS). Six circular UAV flights were conducted at viewing zenith angles from 10° to 60° using a non-imaging hyperspectral sensor, with continuous ground-based irradiance measurements used to derive HDRF values in the 400–850 nm range. Ross–Li model fitting achieved high accuracy (R2 > 0.968), while residual analysis identified systematic discrepancies associated with forward-scattering geometry and secondary illumination from nearby solar towers, with local residuals up to 4.5%. These results highlight the value of dense angular sampling and rapid UAV-based measurements for interpreting field-measured HDRF and for the informed application of reflectance models in calibration environments.

Fields of Study & Subjects

Calibration and Measurement Techniques Remote Sensing in Agriculture Remote-Sensing Image Classification

Publication details

Journal / source
Remote Sensing
Publisher
MDPI AG
Volume
18
Issue
5
Pages
674–674
Publication date
24 February 2026
Language