Abstract

Optical coherence tomography (OCT) is a non-invasive, high-resolution imaging technique widely used in medical diagnosis, biomedical research and other fields. It plays an important role in the early detection and accurate diagnosis of diseases. The superluminescent light-emitting diode (SLED) is the ideal light source for OCT systems, where the stability of its drive current and operating temperature directly determines the imaging quality of OCT. Existing driving and temperature control schemes for similar light sources predominantly rely on microcontrollers or field programmable gate arrays (FPGAs), a reliance which often results in complex system architectures and difficulties in balancing simplicity with control precision. To address these issues, a stable and compact SLED source driver module designed for OCT was developed in this study, integrating both a constant-current drive circuit and a temperature control circuit. The negative feedback control and improved current-limiting protection are employed in the constant-current drive circuit to maintain stable SLED operation and reduce the circuit footprint. A miniature dedicated temperature control chip is adopted in the temperature control circuit. The operating temperature of the SLED is acquired by linearizing the negative temperature coefficient (NTC) thermistor value and regulated through a proportional-integral-derivative (PID) compensation circuit. The size of the fabricated module (including casing) is less than 10 × 8 × 3 cm3. Experimental results show that the driver module achieves a drive current control accuracy of 0.1% and a temperature control accuracy of 0.01 °C. The output optical power fluctuation is less than 0.005 mW and the average axial resolution for OCT is 6.5992 μm with a standard deviation of 0.0107 μm. This light source driver module successfully balances control precision with structural simplicity, demonstrating excellent applicability in OCT systems.

Fields of Study & Subjects

Optical Coherence Tomography Applications Semiconductor Lasers and Optical Devices Optical Systems and Laser Technology

Publication details

Journal / source
Sensors
Volume
26
Issue
7
Pages
2084–2084
Publication date
27 March 2026
Language
EN