A Study on Developing Test Methods for Performance and Reliability Evaluation Based on Failure Analysis of Drainage Pumps used in Sewage Treatment Facilities
Summary
No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.
Summarise with VIRAT Free to try with your Science Catalogs account.Abstract
This study presents the establishment of test methods for systematically evaluating the performance and reliability of drainage pumps, which are key components in water treatment facilities such as stormwater treatment plants and wastewater treatment plants. Failure Modes and Effects Analysis (FMEA) was applied to identify potential failure modes of drainage pumps, and reliability test items were defined with an emphasis on failure modes critical to system operation. For performance evaluation, test methods for total head and efficiency were designed in accordance with KS B 6301. In terms of reliability evaluation, based on the results of FMEA, a dredging performance test and a seizure test were developed to assess the potential for clogging and seizure phenomena that may occur during long-term standby conditions. The integrated test procedure proposed in this study provides a structured approach for evaluating both performance and reliability of drainage pumps used in water treatment facilities.
Fields of Study & Subjects
Reliability and Maintenance Optimization
Cavitation Phenomena in Pumps
Water Systems and Optimization
Publication details
- Journal / source
- Society for Standards Certification and Safety
- Volume
- 16
- Issue
- 1
- Pages
- 173–183
- Publication date
- 27 March 2026
- Language