Valores de Normalidade para Ressonância Magnética Cardiovascular: Uma Revisão Analítico-Comparativa com Ênfase na População Brasileira

Read full text
Authors: Jorge A. Torreão, I Costa, Antonildes N. Assunção-Jr, Ilan Gottlieb, Leonardo Sara da Silva, Tiago Senra, T. S. Magalhães, Marly M. Uellendahl, Hugo Bizetto Zampa, Gabriela Liberato, Walther Yoshiharu Ishikawa, Henrique Trad
+8 more Marcelo Hadlich, Otávio Coelho-Filho, Roberto Sasdelli, Juliano Lara Fernandes, Luíz Francisco Rodrigues de Ávila, Ibraim Masciarelli F. Pinto, Paulo Roberto Schvartzman, Carlos E Rochitte
Cited by: 1
References: 28

Abstract

BACKGROUND: Cardiovascular magnetic resonance (CMR) is the reference standard for morphofunctional cardiac assessment. In Brazil, the application of international normal reference values faces challenges related to population admixture, technical heterogeneity among centers, and the absence of national standardization, all of which may affect diagnostic accuracy. OBJECTIVES: To compare normal reference values for morphofunctional parameters obtained by CMR between a multicenter international review and a Brazilian publication, discussing concordance, methodological differences, and implications for Brazilian clinical practice. METHODS: An analytical-comparative review was performed using summarized data from an international reference-value review and a Brazilian study. Means and standard deviations of key ventricular variables were compared, with assessment of 95% CI overlap, Welch's t-test, and effect size (Hedges' g). Standard-deviation-based cut-off points were proposed for grading abnormality. RESULTS: Overall concordance between means was observed for most variables. Statistically significant differences occurred in a few parameters, mainly ventricular diameters and left ventricular mass, with small to moderate effect sizes. Discrepancies were largely attributed to methodological differences in measurement and indexation. CONCLUSIONS: International normal reference values may be used in Brazilian clinical practice, provided they are adjusted for body surface area and interpreted in light of local particularities. Standardization of protocols and national multicenter studies are needed to strengthen regional validation. Keywords: Normal Values, Cardiac Magnetic Resonance, Reference Interval.

Fields of Study & Subjects

Cardiovascular Function and Risk Factors Cardiac pacing and defibrillation studies Cardiac Imaging and Diagnostics

Publication details

Journal / source
Arquivos Brasileiros de Cardiologia
Publisher
Sociedade Brasileira de Cardiologia
Volume
123
Issue
6
Pages
e20250862–e20250862
Publication date
1 January 2026
Language