Assessment of Staff Dose Loads During Computer Tomography-Guided Biopsy
Summary
No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.
Summarise with VIRAT Free to try with your Science Catalogs account.Abstract
Purpose : To assess the radiation exposure of personnel during biopsy of lung cancer patients under X-ray computed tomography control (CT) and to justify the need to implement specialized technologies to reduce and prevent radiation exposure to personnel. Materials and methods : Measurement of the radiation dose in the X-ray computed tomography beam on the surgeon’s hands, organs of vision and thyroid gland for all stages of puncture taking without taking into account the attenuation of radiation in the surgeon’s protective apron and taking it into account was carried out using a RadiaScan-801M dosimeter. The measurement of the equivalent dose in the surgeon’s head and neck area for all stages of biopsy taking, taking into account the apron on the patient and on the Alderson Rando anthropomorphic phantom, was carried out using two dosimeters: RadiaScan-801M and DKS-AT1123. Results : It has been shown that the maximum equivalent doses received by the surgeon during biopsy procedures were received by the hands, located within the scanning beam. The head and neck areas are significantly exposed to scattered X-ray radiation. The average equivalent dose and average dose rate for all biopsy stages were D = 1850 ± 874 μSv, Ḋ̅ = 21 ± 2 μSv/s. However, given the specific propagation of scattered X-rays during CT scanning due to tube rotation, radiation protective goggles cannot fully perform their function. The average equivalent dose in the head and neck area and average equivalent dose rate were D = 148.8 ± 116 μSv and Ḋ̅ = 1.5 ± 0.5 μSv/s, respectively. An additional simple method for reducing scattered radiation levels is proposed and validated, the effectiveness of which was demonstrated in a phantom experiment. Several ways to reduce radiation exposure through process automation are discussed. Conclusion : The obtained results indicate the need to find measures to make CT-guided biopsy procedures safer while minimizing radiation exposure to personnel
Fields of Study & Subjects
Radiation Dose and Imaging
Advanced Radiotherapy Techniques
Dental Radiography and Imaging
Publication details
- Journal / source
- Journal of oncology diagnostic radiology and radiotherapy
- Volume
- 9
- Issue
- 1
- Pages
- 77–89
- Publication date
- 28 March 2026
- Language
- EN