Isocentric precision study on Shanghai Proton Therapy Device 360° compact gantry

Read full text Summarise with VIRAT
Authors: Yunjing WANG, Jun WU, Wencheng Fang, Zhentang ZHAO
Cited by: 0
References: 10

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

BackgroundShanghai Advanced Proton Therapy Device (SAPT) is the first domestic proton therapy demonstration device, and the gantry is an important part of the proton therapy device, with an isocentric accuracy of ±0.275 mm, which is superior to most of the international mainstream equipments and requires high motion positioning accuracy and reliability.PurposeThis study aims to provide a reference for the impact of the gantry structure on the treatment accuracy of the gantry of proton therapy device under different rotation angle conditions.MethodsFirstly, the development progress of the 360° gantry for SAPT located in the Shanghai Ruijin Hospital proton center was introduced, and its isocentric accuracy was presented in detail. Then, deformation analysis of the gantry center point was carried out through the static structural analysis module of ANSYS. Finally, the actual deformation was measured using a laser tracker, and the error sphere was plotted to determine the accuracy at the center point under typical working conditions and analyze the causes.ResultsThe qualitative analysis of the isocentric accuracy during the gantry rotation process shows that the trend of simulation results is consistent with the measured data (correlation coefficient R2 ≥ 0.92). The simulation predicts an overall isocentric accuracy of ±0.25 mm, while the measured result is ±0.275 mm, with a deviation rate < 10%, which is superior to international mainstream equipment (typically < ±1 mm). However, there is a certain deviation in the Z-axis direction (average deviation about 0.05 mm), which is attributed to mechanical installation errors not included in the simulation.ConclusionsThe simulation results of this study demonstrate that the stiffness, strength and stability of the gantry structure are at an excellent level, providing solid theoretical support for subsequent engineering applications. The successful development of China's first 360° gantry with ultra-high isocentric precision (±0.275 mm) represents not only a milestone in the localization of high-end medical equipment, but also achieves leading international level with innovative structure and cost advantages.

Fields of Study & Subjects

Advanced Radiotherapy Techniques Radiation Therapy and Dosimetry Advanced Measurement and Metrology Techniques

Publication details

Journal / source
Nuclear Techniques
Volume
49
Issue
3
Pages
030202–030202
Publication date
1 March 2026
Language
EN