Development of an exosuit for people with upper-limb impairments
Summary
No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.
Summarise with VIRAT Free to try with your Science Catalogs account.Abstract
Our arms play a critical role in nearly every aspect of our daily lives. We rely on the complex coordinated movement of our shoulders, elbows, and hands to interact with our environment, manipulate objects, and express ourselves socially. The shoulder stands out as a fundamental and complex structure, acting as the base for these necessary movements. Upper limb impairments, whether due to neurological disorders, musculoskeletal injury, or congenital diseases, can effect the shoulder in many ways, but in particular a common symptom is muscular weakness. Excessive weakness in the shoulders can limit independence and quality of life by compromising the ability to reach and interact with ourselves and objects. For patients undergoing neuro-rehabilitation, regaining this strength and training functional movements is prioritized, while for people with congenital or degenerative conditions, managing or delaying weakness progression is a primary objective. Robotic devices have been long used in conjunction with traditional therapy approaches, but so far most commercially available solutions are large, heavy, complex, arm exoskeletons and support devices, and thus remain stationary tools within clinics. Recently, portable wearable robotic systems, often referred to as exosuits, have emerged as a promising technology that can span the continuum of care, suitable for intensive rehabilitation in the clinic, as tools for remote tele-therapy, and finally for use as assistive devices during daily life. Despite significant advances in exosuit technologies many research prototypes are still constrained to supervised testing and validation in laboratory or clinical environments. These limitations point to opportunities for enhancing simplicity, portability, and usability, and can lead to possibilities for studies with untethered and unsupervised use. Furthermore, while initial studies on various devices have demonstrated reduced muscle fatigue, there is a need for user testing with larger and broader patient populations to quantify how this support translates to measurable improvements in activity performance. Finally there is a need to explore real-world usability and acceptance outside of supervised settings to understand how the effects of the device translate into tangible benefits. To bridge this gap we developed and validated an exosuit for shoulder support that could be used for therapy, rehabilitation, and assistance. The target population were people that have remaining (residual) function in their arms, but due to muscular weakness, still struggle training or performing activities independently. Both acquired and congenital pathologies were considered, and as well supervised clinical and independent home use-cases were evaluated during the development of the exosuit. Patient and therapist feedback was continuously incorporated during development, so as to integrate desirable features and functions into the prototype generations. First, we researched designs and controllers to simplify cable-driven exosuits. A novel sensorless control algorithm was developed to eliminate the need for a distal load cell in the transmission system, reducing complexity and potential points of failure. The resulting tension tracking errors (ranging from 6.14N to 8.17N at 50% gravity support) were higher than state of the art tracking errors with load-cell dependent indirect force controllers (3.40N at 70% gravity support), but the final system could still significantly reduce muscular activity in the primary agonist muscle groups for arm elevation (anterior deltoid, trapezius, and pectoralis major demonstrated decreases of -30%, -38%, and -38%, respectively). This work was coupled with an extensive kinematic analysis of the upper-limb during activities of daily living to inform and optimize the new hardware design. A new, lightweight, two degree of freedom tendon driver unit (1.7kg) and textile interface was developed, coming together to create the Myoshirt. The increased portability and modularity of the exosuit enabled bi-manual shoulder support and paved the way for untethered and unsupervised use. Then the effects of the exosuit were quantified in a supervised clinical setting with impaired participants. Results demonstrated that gravity support led to increased endurance (+78.7% average time in static elevation task), increased elbow extension (+13.5% extension angle during a functional drinking task), reduced perceived task difficulty, and improved execution quality. During non-functional range of motion tasks, elbow ROM decreased -13.2%, likely due to interference with the upper-arm cuffs. Going beyond controlled interventions, the Myoshirt was deployed in three longitudinal two week case studies with a heterogeneous group of impaired users in clinical and home environments, exploring acceptance and usability. While results from the clinical use-cases demonstrated promising benefits and garnered strong interest from the users and therapists, the case study in unsupervised home use highlighted that donning ease, comfort, and aesthetics were critical factors that inhibited regular and sustained usage. The work in this thesis shed light on how upper-limb exosuits can be simplified, applied in controlled clinical environments, and longitudinally for exercise, therapy, and daily assistance. Along with the promising controller developments, kinematics research, electromechanical contributions, and clinical tests, we present as well pioneering work deploying the Myoshirt to users who integrated it into their therapy sessions and daily lives to obtain honest feedback. All of these studies collectively have answered many questions, and revealed even more open challenges, which are now jumping points for future promising research opportunities. The portable, simplified, and modular exosuit design presented in this dissertation successfully advances our understanding of exosuit technology and provides a platform for further research. Ultimately, we are now closer to demonstrating the practical utility of soft upper-limb exosuits in spanning the transition from clinical therapy to continuous, independent support in everyday life, and enabling users to significantly improve the quality of their lives.
Fields of Study & Subjects
Prosthetics and Rehabilitation Robotics
Stroke Rehabilitation and Recovery
Muscle activation and electromyography studies
Publication details
- Publication date
- 1 January 2026
- Language
- EN
- Document type
- Thesis