Comparative evaluation of abutment screw loosening with two different thread lockers under cyclic loading: An in vitro study

Read full text
Authors: Lizy Teena Arul, Vidyashree Nandini Venugopal, Russia Marimuthu, Sarthak Ray Arindham, Manjula Gunasekeran
Cited by: 0
References: 15

Abstract

AIM: To evaluate and compare the effects of different thread lockers on implant abutment screw loosening. SETTINGS AND DESIGN: An in-vitro study. MATERIALS AND METHODS: Thirty implant-abutment assemblies were divided into 3 groups: Control group (without threadlocker), dimethacrylate group, and methacrylate group. Each group was subdivided into static and dynamic groups. The specimens were torqued to 35 Ncm, and detorque values were measured after 1 month in static conditions and after cyclic loading. The cyclic loading protocol involved 240,000 cycles at a velocity of 16 mm/s over a 48-h period in a moist environment, simulating 1 year of clinical function. STATISTICAL ANALYSIS USED: Two-way ANOVA tests were applied to assess intergroup comparisons of detorque values (Ncm) under static and dynamic conditions. RESULTS: Results were assessed using one-way, two-way ANOVA and multiple pairwise comparisons with a significance level of P ≤ 0.05. The methacrylate group demonstrated the highest detorque values (static: 36.46 ± 0.95 Ncm, dynamic: 33.22 ± 0.34 Ncm), followed by the dimethacrylate group (static: 32.84 ± 1.12 Ncm, dynamic: 29.98 ± 1.05 Ncm). The control group exhibited the lowest detorque values (static: 28.80 ± 0.96 Ncm, dynamic: 25.84 ± 0.63 Ncm). Detorque values were consistently higher in the static condition (32.40 ± 3.37 Ncm) compared to the dynamic condition across all groups (29.68 ± 3.20 Ncm), with statistically significant differences observed (P = 0.000). CONCLUSION: Within the limitations of the study, application of threadlockers significantly improved abutment screw retention, with methacrylate exhibiting superior performance over dimethacrylate. The reduction in detorque values under cyclic loading highlights the need for enhanced retention strategies in implant prosthetics. Incorporating methacrylate-based threadlockers in clinical practice may mitigate screw loosening and enhance the long-term success of implant-supported prostheses.

Fields of Study & Subjects

Dental Implant Techniques and Outcomes Facial Trauma and Fracture Management Surgical Sutures and Adhesives

Publication details

Journal / source
The Journal of Indian Prosthodontic Society
Volume
26
Issue
1
Pages
49–55
Publication date
1 January 2026
Language
EN