Large-scale evaluation of multimodal large language models for pneumothorax detection

Read full text
Authors: Hamza Eren Güzel, Cemre Özenbaş, Ali Murat Koç
Cited by: 2
References: 20

Abstract

Large-scale evaluation of multimodal large language models for pneumothorax detection PURPOSE Pneumothorax requires rapid recognition and accurate interpretation of chest X-rays (CXRs), particularly in acute settings where delays can have serious consequences.With the emergence of advanced image interpretation models capable of visual analysis, their diagnostic reliability in radiology practice remains to be determined.This study aimed to assess the diagnostic performance of three state-of-the-art systems in detecting pneumothorax using a large, well-annotated dataset. METHODSA total of 10,675 CXRs from the publicly available SIIM-ACR Pneumothorax Segmentation dataset were analyzed.Three multimodal models (GPT-4o, Gemini 2 Pro, and Claude 4 Sonnet) were evaluated using a uniform, image-based approach.Each model's binary outputs (presence: 1, absence: 0) were compared with reference results to determine accuracy, sensitivity, specificity, precision, and F1 scores.Additional subgroup analyses were conducted across pneumothorax size categories: small, medium, and large.Pairwise statistical comparisons were performed using McNemar's test.Sensitivity, specificity, and overall accuracy are reported with corresponding 95% confidence intervals. RESULTSThe prevalence of pneumothorax in the dataset was 22.3% (n = 2,379).All models demonstrated high specificity (above 0.90) but consistently low sensitivity (0.16-0.36).The best overall performance was observed with Gemini 2, which achieved an accuracy of 0.79 and specificity of 0.95, whereas Claude 4 showed greater sensitivity (0.20-0.34) across lesion-size categories.Diagnostic performance improved with increasing pneumothorax size, but smaller lesions remained difficult to identify.Pairwise comparisons confirmed statistically significant differences among all evaluated systems (P < 0.050). CONCLUSIONIn this large-scale evaluation, the tested models exhibited strong reliability in identifying normal examinations but limited ability to detect subtle or small pneumothoraxes.Despite high specificity, low sensitivity limits the use of current Multimodal large language models as rule-out tools for pneumothorax.With continued refinement, these models may eventually support radiologists by improving workflow efficiency and diagnostic confidence. CLINICAL SIGNIFICANCEAutomated systems capable of high specificity but low sensitivity should not be relied upon to exclude pneumothorax.However, they may serve as valuable assistants for confirming positive findings and prioritizing urgent cases in busy clinical workflows.

Fields of Study & Subjects

Machine Learning in Healthcare Topic Modeling Artificial Intelligence in Healthcare and Education

Publication details

Journal / source
Diagnostic and Interventional Radiology
Publisher
Galenos Yayinevi
Volume
32
Issue
5
Pages
585–590
Publication date
12 February 2026
Language
EN