Homemade Glove-Port Platform for Ovarian Teratoma Resection in Laparoscopic Single-Site Surgery

Read full text
Authors: Dayuan Huang, Wenchen Huang, Haiyan Chen, Qiong Yang
Cited by: 1

Abstract

Background: The adoption of laparoscopic single-site surgery (LESS) is limited by the high cost of commercial platforms. We present a self-designed glove-port for LESS ovarian teratoma resection. Technique: A single-port platform was constructed from a surgical glove and rings from a disposable suction tube. A specimen retrieval bag was modified with a silk drawstring and a secondary opening to create a closed system. The teratoma was dissected within the closed bag and all contents were removed via the umbilicus. Results: The procedure was successfully performed. The self-assembled port provided stable access, and the modified bag enabled complete specimen containment and extraction without spillage or auxiliary incisions. Conclusion: This technique demonstrates a safe, feasible, and low-cost alternative for LESS. Utilizing ubiquitous materials improves the accessibility of minimally invasive, cosmetically favorable surgery in resource-constrained settings.

Fields of Study & Subjects

Minimally Invasive Surgical Techniques Teratomas and Epidermoid Cysts Surgical Sutures and Adhesives

Publication details

Journal / source
JSLS Journal of the Society of Laparoscopic & Robotic Surgeons
Publisher
The Society of Laparoscopic and Robotic Surgeons
Volume
30
Issue
1
Pages
e2025.00101–e2025.00101
Publication date
1 January 2026
Language