Comparison of ease of intubation with Airtraq optical laryngoscope versus Macintosh laryngoscope in pediatric patients undergoing elective surgeries
Abstract
Background: The AirTraq optical laryngoscope has been extensively evaluated in adults; it improves the ease of intubation and is associated with less movement of the cervical spine. Studies on pediatric patients are necessary due to the differences in airway in comparison with adults. This study aimed to compare the ease of intubation with AirTraq and Macintosh laryngoscopes in pediatric patients as primary objective and hemodynamic changes and airway trauma as secondary objectives. Methods: 60 children of American Society of Anaesthesiologists (ASA) class I-II, aged 1-7 years of either sex posted for routine surgery requiring tracheal intubation were randomly divided into 2 groups; Group-A AirTraq (n = 30) and Group-B Macintosh (n = 30). Intubation time, number of attempts, percentage of glottic opening (POGO) score, Visual Analogue Scale (VAS) were recorded. Hemodynamic variables noted at baseline, immediately after intubation (T0), 1, 3, and 5 min after intubation (T1, T2, T3). Airway trauma (if any) during intubation was also noted. Results: The use of AirTraq in comparison with Macintosh laryngoscope was associated with shorter intubation time [(15.83±3.949s) and (19.83±5.066s), P=0.001], better POGO score (p
Fields of Study & Subjects
Airway Management and Intubation Techniques
Anesthesia and Sedative Agents
Tracheal and airway disorders
Publication details
- Journal / source
- Ethiopian Journal of Pediatrics and Child Health
- Volume
- 21
- Issue
- 1
- Pages
- 53–62
- Publication date
- 1 January 2026