Investigasi Penyebab dan Penanggulangan Kinerja Sistem Oily Water Separator di Kapal MT. Vivit Africa LNG
Abstract
This study aims to investigate the causes and countermeasures for the performancedegradation of the Oily Water Separator (OWS) system on board the MT. Vivit Africa LNG. Theresearch employs a qualitative approach through observation, interviews, documentation, andliterature review. The findings indicate that the decline in OWS performance is caused by amalfunctioning bilge circulating pump, contaminated fluid quality, suboptimal electric heatertemperature, and delays in spare parts replacement. The impacts include reduced pump pressure,sludge accumulation, and potential operational disruptions. Countermeasures taken include pumprepairs, cleaning of filters and heaters, and improvement in spare parts logistics management. Thestudy recommends preventive maintenance, regulation of pump operations, and real-timemonitoring to maintain the efficiency and safety of the OWS system.
Fields of Study & Subjects
Marine and Offshore Engineering Studies
Technical Engine Diagnostics and Monitoring
Marine and Coastal Research
Publication details
- Journal / source
- Indonesian Journal of Marine Engineering
- Volume
- 3
- Issue
- 1
- Pages
- 28–39
- Publication date
- 2 February 2026