Abstract

Introduction. Optical clearing has enabled three-dimensional visualization of brain tissue, but available methods differ in their ability to preserve morphology, achieve maximum effective imaging depth, and maintain fluorescent signal quality while minimizing unwanted background fluorescence. Objective. To evaluate the optical and morphological performance of tissue-clearing protocols applied to immunostained brain structures through a systematic review with descriptive quantitative synthesis of studies published between 2014 and 2024. Method. Experimental studies using human or rodent brain tissue combining optical clearing and immunostaining were identified through searches in Scopus and Web of Science following the PRISMA 2020 guidelines. Data were synthesized using descriptive statistics, group comparisons, non-parametric correlations, and exploratory regression analyses. Bibliometric network analyses were conducted using the software VOSviewer. Results. Twelve experimental studies met the inclusion criteria. Organic solvent–based methods (iDISCO+, uDISCO) showed higher descriptive values of maximum effective imaging depth and lower levels of unwanted background fluorescence compared to hydrogel-based and hydrophilic approaches. Maximum effective imaging depth was significantly associated with reduced unwanted background fluorescence (ρ = –0.596; p = 0.041), while its association with fluorescent signal quality showed a non-significant positive trend (ρ = 0.570; p = 0.053). Conclusion. Organic solvent–based clearing methods exhibited more favorable descriptive optical profiles, particularly with respect to imaging depth and background suppression. However, in the absence of statistically significant between-group differences, these findings should be interpreted as suggestive patterns rather than definitive evidence of superiority.

Fields of Study & Subjects

Advanced Fluorescence Microscopy Techniques Optical Imaging and Spectroscopy Techniques Cell Image Analysis Techniques

Publication details

Journal / source
Revista de Investigación e Innovación en Ciencias de la Salud
Volume
8
Issue
2
Pages
1–27
Publication date
20 March 2026
Language
EN