Thermodynamic and Short-Circuit Performance of Rigid Overhead Contact Systems in Ho Chi Minh City Line 1 Metro Tunnels

Read full text
Authors: Thai Nguyen, Dong Doan Van, Son Nguyen Dinh
Cited by: 1
References: 5

Abstract

This paper presents a rigorous electro-thermal evaluation and safety margin analysis comparing the Advanced Rigid Overhead Contact System (ROCS, 2100 mm2) and conventional Flexible OCS (170 mm2) in Ho Chi Minh City Metro Line 1. Utilizing interconnected mathematical frameworks, the study models both dynamic transient load profiles and worst-case short-circuit scenarios. Simulation results reveal that under a 25.78 kA fault lasting 1 s, the OCS suffers severe thermal shock, violently surging to 155.0 °C and breaching its mechanical annealing threshold. Conversely, the massive aluminum ROCS acts as an effective heat sink, restricting fault temperatures to a safe 36.6 °C. Under continuous cyclic operational loading with a 2.1 min headway, the ROCS demonstrates high thermal inertia, constraining transient spikes to 21.5 °C and stabilizing its long-term temperature rise within a bounded stability band (35 °C to 65 °C) below the 79 °C cyclic saturation limit. These findings mathematically prove the superior climate resilience and structural safety margins of ROCS for high-capacity tropical underground transit networks.

Fields of Study & Subjects

Thermal Analysis in Power Transmission Electrical Contact Performance and Analysis Railway Systems and Energy Efficiency

Publication details

Journal / source
Engineering Technology & Applied Science Research
Publisher
Engineering, Technology & Applied Science Research
Volume
16
Issue
4
Pages
38248–38253
Publication date
11 August 2026