Comp2Comp: Open-Source Software with FDA-Cleared Artificial Intelligence Algorithms for Computed Tomography Image Analysis

Read full text
Authors: Adrit Rao, Malte Jensen, Andrea T. Fisher, Louis Blankemeier, Pauline M. Berens, Arash Fereydooni, Seth T. Lirette, Eren Alkan, Felipe C. Kitamura, Juan Manuel Zambrano Chaves, Eduardo Pontes Reis, Arjun Desai
+19 more Marc H. Willis, Jason Hom, Andrew Johnston, Leon Lenchik, Robert Downey Boutin, Eduardo Moreno Júdice de Mattos Farina, Augusto Sarquis Serpa, Marcelo S. Takahashi, Jordan D. Perchik, Steven Rothenberg, Jamie Schroeder, Ross W. Filice, Leonardo Kayat Bittencourt, Hari Trivedi, Marly van Assen, John Mongan, Kimberly G. Kallianos, Oliver Aalami, Akshay Sanjay Chaudhari
Cited by: 0

Abstract

Artificial intelligence allows automatic extraction of imaging biomarkers from already-acquired radiologic images. This paradigm of opportunistic imaging adds value to medical imaging without additional imaging costs or patient radiation exposure. However, many open-source image analysis solutions lack rigorous validation while commercial solutions lack transparency, leading to unexpected failures when deployed. Here, we report development and validation for two of the first fully open-sourced, FDA-510(k)-cleared deep learning pipelines to mitigate both challenges: Abdominal Aortic Quantification (AAQ) and Bone Mineral Density (BMD) estimation are both offered within the Comp2Comp package for opportunistic analysis of computed tomography scans. AAQ segments the abdominal aorta to assess aneurysm size; BMD segments vertebral bodies to estimate trabecular bone density and osteoporosis risk. AAQ-derived maximal aortic diameters were compared against radiologist ground-truth measurements on 258 patient scans enriched for abdominal aortic aneurysms from four external institutions. BMD binary classifications (low vs. normal bone density) were compared against concurrent DXA scan ground truths obtained on 371 patient scans from four external institutions. AAQ had an overall mean absolute error of 1.57 mm (95% CI 1.38-1.80 mm). BMD had a sensitivity of 81.0% (95% CI 74.0-86.8%) and specificity of 78.4% (95% CI 72.3-83.7%). Comp2Comp AAQ and BMD demonstrated sufficient accuracy for clinical use. Open-sourcing these algorithms improves transparency of typically opaque FDA clearance processes, allows hospitals to test the algorithms before cumbersome clinical pilots, and provides researchers with best-in-class methods.

Fields of Study & Subjects

Artificial Intelligence in Healthcare and Education Medical Image Segmentation Techniques Medical Imaging and Analysis

Publication details

Journal / source
arXiv (Cornell University)
Publication date
10 February 2026
Language
EN
Document type
Preprint