Determining Drying Conditions to Mitigate Hanford Double Shell Storage Tank Underside Corrosion — Phase 1

View at publisher
Authors: Benjamin Barkai, Kiana Sykes, Pavan K. Shukla, Tasnia Fatima, Roderick E. Fuentes, Bruce J. Wiersma, Crystal L. Girardot, Jason S. Page, Shawn Campbell
Cited by: 0

Abstract

Abstract The Hanford Site in Washington State has legacy radiological waste that is being retrieved from single shell tanks (SSTs) and transferred to newer, double shell tanks (DSTs) for eventual closure of the SSTs. The waste is maintained in the DSTs until eventual immobilization can be performed at the Waste Treatment and Immobilization Plant (WTP), currently under construction. Until full immobilization is complete, extended service of the DSTs must be ensured by mitigating corrosion of the steel tank walls and buried steel pipelines. A Pit Air Supply System has been developed to mitigate corrosion of the leak detection pits connected to the concrete foundations of the DSTs. The objectives for the present study are: (i) to corrode steel specimens in an electrolytic simulant to form artificial pits with specific pit depths, and (ii) to determine the temperature and humidity levels that will mitigate further pit growth. Experimental work and results will be presented to evaluate conditions associated with the PASS system and predict corrosion rates when the PASS is operating.

Fields of Study & Subjects

Corrosion Behavior and Inhibition Nuclear and radioactivity studies Structural Integrity and Reliability Analysis