Synovial fluid α -defensin might be false positive in early stages after major total arthroplasty revision surgery
Abstract
Generalizability is critical when evaluating the performance of a diagnostic test to ensure variations in the patient population are represented. We report a case of a patient receiving multiple false positive results from the synovial α -defensin test observed over close to a 3-year period following revision total knee arthroplasty.
Fields of Study & Subjects
Antimicrobial Peptides and Activities
Osteoarthritis Treatment and Mechanisms
Orthopedic Infections and Treatments
Publication details
- Journal / source
- Journal of Bone and Joint Infection
- Volume
- 11
- Issue
- 1
- Pages
- 1–4
- Publication date
- 7 January 2026
- Language
- EN