The effect of WALANT on outcomes of flexor tenolysis
Summary
No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.
Summarise with VIRAT Free to try with your Science Catalogs account.Abstract
The incidence of tenolysis after flexor tendon surgery is approximately 5 to 15%, even if updated and adequate techniques are used.[1,2] Various elements play a role in the development of peritendinous adhesions, such as the initial injury to the tendon and its surrounding sheath, the technical details of the surgical repair, and the immobilization of the tendon during the rehabilitation phase.[3] Flexor tenolysis is an established surgical procedure to restore mobility to the flexor tendon by lysing adhesions that inhibit tendon gliding and negatively impact functional outcomes following flexor tendon repair.[3] While there are reports regarding the tenolysis outcomes are often unsatisfactory and suboptimal with re-adhesions and other complications, [4] literature contains reports that support favorable outcomes can be achieved by tenolysis.[5,6] The wide-awake local anesthesia no tourniquet (WALANT) technique has been increasingly usedObjectives: This study aims to evaluate the outcomes of the flexor tenolysis cases with wide-awake local anesthesia no tourniquet (WALANT) and to compare them with cases with other anesthesia types.Patients and methods: Between March 2004 and March 2024, a total of 104 patients with 150 fingers with flexor tenolysis (71 males, 33 females; mean age: 32.67 ± 11.64 years; range, 16 to 62 years) were included in the study.The WALANT group consisted of 41 patients with 53 fingers, while the conventional anesthesia group consisted of 63 patients with 97 fingers.Pre-and postoperative total active motion (TAM) gains were compared between the two groups and relevant factors were investigated.Results: Overall TAM gain was 47% in our study cohort.The TAM gain was 55% and 43% in the WALANT group and in the conventional anesthesia group, indicating a statistically significant difference (p = 0.005).The best TAM gains were observed in the clean-cut injury type.The TAM gains were better in the cases without fractures.Age was a significant factor in the tenolysis outcomes, and younger patients had improved outcomes.Conclusion: Our study results indicate a significant difference in the TAM gain between the WALANT and conventional methods.Taken together, we believe that the application of WALANT in tenolysis of flexor tendon adhesions represents a significant advancement in hand surgery.The ability to perform the procedure under local anesthesia while allowing for immediate assessment of tendon function enhances the surgical precision and results.
Fields of Study & Subjects
Orthopedic Surgery and Rehabilitation
Vascular Procedures and Complications
Tendon Structure and Treatment
Publication details
- Journal / source
- Joint Diseases and Related Surgery
- Volume
- 37
- Issue
- 2
- Pages
- 510–518
- Publication date
- 17 March 2026
- Language
- EN