D3.2 - EMR Component Report

Read full text
Authors: Luiz Guilherme Enger, Jérémy Létang, Nikolaos Fotias
Cited by: 0

Abstract

This document, D3.2 – EMR Component Report, defines the design, fabrication, characterization and testing of the magnetoresistive (MR) component. The document discusses: - The choice of material for the MR component in the context of NOVETROL project - The differences between developing a MR device for sensing applications based on the effect commonly labelled as extraordinary magnetoresistance (EMR) and developing a MR device for current limiting applications - The development of analytical expressions to estimate the resistance of the MR element with and without the presence of a magnetic field as a function of geometry and relevant material properties - The modelling and simulation of such devices via Finite Element Modelling (FEM) approach using commercial software - The fabrication procedure followed in clean room environment to obtain the desired components as designed - The characterization steps used in the Magnetics Laboratory to obtain experimental data from the samples, and understand their electrical and magnetic behaviour From requirements defined previously in D2.1 - Report on NOVETROL Use Cases and Scenarios and D3.1 - System Specifications, a set of resistance values at zero and high magnetic fields for each use case can be obtained, which will guide the design of the MR elements.

Fields of Study & Subjects

Magnetic Field Sensors Techniques Magnetic properties of thin films Magnetic Properties and Applications

Publication details

Journal / source
Zenodo (CERN European Organization for Nuclear Research)
Publication date
29 January 2026