COMPARATIVE CFD STUDY OF HEAT TRANSFER CHARACTERISTICS IN TOP AND BOTTOM JET IMPINGEMENT COOLING

Read full text Summarise with VIRAT
Authors: Obinna Michael Onoh, Joseph Chinedu Okafor, Chisom Benedicta Onyekachi
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Jet impingement heat transfer was studied using top and bottom surface stationary cooling configuration. Using rectangular steel plates of 230mm by 120mm by 12mm, and single jet diameters of 10mm and 40mm with impingement gaps of 115mm and 155mm. Experimental data were reduced by lumped thermal mass analysis model for calculating convective heat transfer coefficient and ANSYS CFD software was used to validate experimental results. The results analyzed by lumped thermal mass analytical showed that, for a diameter 10mm and impingement gap of 115mm, the Top surface showed bettercontrolled cooling with a 63% difference, and at impingement gap, 155mm top surface maintained better cooling with a 66% difference for a diameter 40mm. The calculated convective heat transfer coefficient increases with an increase in pipe diameter and a corresponding increase in impingement gaps in both cooling processes. The CFD results revealed maximum heat fluxes of 22518W/m2 and 6742.8w/m2 for the top at 10mm and 40mm diameters. This proved top surface cooling configuration is better than the bottom with maximum heat flux. The validation showed an acceptable error margin for both surfaces with a diameter of 10mm 0.2s/0C for the top surface.

Fields of Study & Subjects

Heat Transfer Mechanisms Heat Transfer and Optimization Heat transfer and supercritical fluids

Publication details

Journal / source
Zenodo (CERN European Organization for Nuclear Research)
Publication date
27 January 2026
Language
EN