Intelligent Changeover Switch Design: A Comparative Study of Single and Three Phase Selector for Efficient Power Distribution

Read full text Summarise with VIRAT
Authors: Nsikakabasi I. Bassey, Bennett S. Isaiah, Ephraim R. Afia, Philip Philip, Felix N. Akam
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

The persistent unreliability of electrical power supply in developing economies, particularly Nigeria characterized by frequent grid outages, voltage fluctuations, and phase imbalances necessitates the development of affordable and dependable automatic changeover solutions for seamless load transfer between grid and backup generation. This paper presents a comparative analysis of a three-phase Automatic Transfer Switch (ATS) system rated for (380V–415 V) and a single-phase ATS system rated for 220V–240 V. Both systems were built using four-pole electromagnetic contactors with mechanical and electrical interlocking, programmable digital and analog timers for switching sequence control, and comprehensive protection devices. Performance evaluation was conducted under controlled laboratory conditions using calibrated instruments; a Fluke 87V multimeter, Kyoritsu 2033 ammeter, and Fluke 435 Series II power quality analyzer with data collected across load conditions ranging from 0% to 100% and over multiple switching events. The findings reveal that the three-phase ATS consistently outperformed the single-phase system across all performance indicators. It achieved substantially faster switching times (4.2s–4.5 s versus 7.5–8.2 s), significantly lower per-phase current draw at equivalent power delivery (3.6 A versus 10.6 A), and superior voltage regulation with only a 1.5% voltage drop at full load compared to 3.0% for the single-phase system. Both configurations exhibited excellent repeatability across multiple switching events, with variations within ±0.3 s, confirming the reliability of the programmable timing and contactor mechanisms. Additionally, the three-phase system maintained acceptable current balance across phases, with a maximum deviation of 0.1 A. These results demonstrate that contactor-based ATS technology offers a practical and affordable solution for power distribution applications in developing economies. The single-phase system provides suitable functionality for residential applications with moderate power demands, while the three-phase configuration delivers optimal performance for commercial and industrial installations requiring minimal voltage fluctuation and faster response times. This study contributes methodological resources for engineering education and technical capacity building in the electrical power sector of developing economies, validates locally manufactured solutions as technically viable alternatives to costly imported equipment, and supplies empirical performance data to support evidence-based ATS selection decisions.

Fields of Study & Subjects

Electric Power Systems and Control Power Quality and Harmonics Microgrid Control and Optimization

Publication details

Journal / source
Zenodo (CERN European Organization for Nuclear Research)
Publication date
2 April 2026
Language
EN