Abstract

This article investigates methods for enhancing the efficiency of gravity-driven ventilation in residential buildings, with particular emphasis on chimney-based passive solutions. Full-scale in situ experiments were conducted in a single-family house located in a temperate climate in northern Poland during a four-month transitional period (August–November). Three chimney configurations were analysed: a traditional ceramic brick chimney (TYPE I), a solar chimney with a transparent glazed enclosure above the roofline (TYPE II), and a traditional chimney equipped with a rotary-type chimney cap (TYPE III).Ventilation performance was evaluated using the air change rate (ACH) under varying wind and solar radiation conditions. The results show that, compared to the reference configuration (TYPE I – traditional chimney), the solar chimney (TYPE II) increased the average ACH by approximately 14%, particularly under low-wind conditions (0–2 m/s) and solar radiation above 100 W/m. The greatest improvement was achieved by the rotary-type chimney cap (TYPE III), which increased the average ACH by about 35%, with maximum values reaching 0.40 h⁻ under wind speeds of 2–5 m/s. These findings demonstrate that passive architectural modifications can significantly enhance gravity-driven ventilation and thereby improve indoor air quality in residential buildings.In addition to ventilation performance, the impact of the rotary chimney cap on heating energy demand was assessed over a 24-month monitoring period. The installation of the chimney cap reduced annual heating energy consumption from 33.74 GJ to 27.21 GJ, corresponding to an energy saving of 6.53 GJ (approximately 19%). The results demonstrate that passive chimney modifications not only enhance gravity ventilation efficiency but also contribute to measurable reductions in heating energy demand, supporting their application in energy-efficient residential buildings.

Fields of Study & Subjects

Solar Energy Systems and Technologies Wind and Air Flow Studies Building Energy and Comfort Optimization

Publication details

Journal / source
Zeszyty Naukowe SGSP
Volume
1
Issue
97
Pages
61–76
Publication date
31 March 2026
Language
EN