Is Bigger Always Bad ? Evaluating Effect of Sedation on MRI-Based Optic Nerve Sheath Diameter Measurements in Children
Abstract
Objectives To assess the impact of sedation on optic nerve sheath diameter (ONSD) as measured by MRI in pediatric patients. ONSD is a widely accepted non-invasive marker for estimating raised intracranial pressure (ICP), but potential effects of sedation on its accuracy remain understudied in children. Materials and Methods A retrospective observational study was conducted on brain MRI scans from pediatric patients aged 0–18 years. Patients were divided into two groups: those who received sedation and those who underwent MRI without sedation. Bilateral ONSD was measured at a standardized point 3 mm posterior to the globe on axial T2-weighted images. Inter-observer agreement was analyzed, and group comparisons used non-parametric statistical methods. Results Out of 78 pediatric patients, 38 received mild sedation and 40 were imaged without sedation. The mean ONSD in the non-sedated group was 4.8 ± 0.3 mm compared to 5.7 ± 0.4 mm in the non-sedated group (p = 0.02). This difference was statistically significant(t(68.5) = -11.2, p <
Fields of Study & Subjects
Traumatic Brain Injury and Neurovascular Disturbances
Cerebral Venous Sinus Thrombosis
Advanced MRI Techniques and Applications
Publication details
- Journal / source
- Swiss Journal of Radiology and Nuclear Medicine
- Volume
- 27
- Issue
- 1
- Pages
- 55–60
- Publication date
- 30 January 2026
- Language
- EN