Evaluation of seroma formation in mesh fixation techniques for inguinal hernia repair
Abstract
Seroma formation is a common complication after Lichtenstein tension-free inguinal hernia repair. Therefore, it is of interest to compare the incidence of seroma formation and related postoperative outcomes among non-absorbable sutures, absorbable sutures and fibrin glue fixation techniques. Hence, a total of 180 patients were randomly assigned to three groups for mesh fixation. Fibrin glue fixation resulted in shorter operative times and less postoperative pain but had a higher incidence of seroma formation. Suture-based fixation methods demonstrated fewer seromas and comparable recurrence and complication rates.
Fields of Study & Subjects
Hernia repair and management
Surgical Sutures and Adhesives
Hip disorders and treatments
Publication details
- Journal / source
- Bioinformation
- Volume
- 22
- Issue
- 1
- Pages
- 84–88
- Publication date
- 31 January 2026
- Language
- EN