Evaluation of seroma formation in mesh fixation techniques for inguinal hernia repair

Read full text
Authors: Kaushlendra Singh Narwariya, Krishna Pratap Singh, Upendra Singh, Pooja Rajput, Vishnu Kumar Gupta, Parul Nema
Cited by: 0

Abstract

Seroma formation is a common complication after Lichtenstein tension-free inguinal hernia repair. Therefore, it is of interest to compare the incidence of seroma formation and related postoperative outcomes among non-absorbable sutures, absorbable sutures and fibrin glue fixation techniques. Hence, a total of 180 patients were randomly assigned to three groups for mesh fixation. Fibrin glue fixation resulted in shorter operative times and less postoperative pain but had a higher incidence of seroma formation. Suture-based fixation methods demonstrated fewer seromas and comparable recurrence and complication rates.

Fields of Study & Subjects

Hernia repair and management Surgical Sutures and Adhesives Hip disorders and treatments

Publication details

Journal / source
Bioinformation
Volume
22
Issue
1
Pages
84–88
Publication date
31 January 2026