Raw data of Assay controls to identify extracellular vesicles as the source of flow cytometry signals

Read full text Summarise with VIRAT
Authors: Lei Zhu
Cited by: 0

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

The most used method to determine the concentration of single immunolabeled extracellular vesicles (EVs) is flow cytometry (FCM). Fluorescent positive events measured by FCM are often attributed to EVs but could result from background noise or non-EV particles, such as aggregated antibodies, fluorophores, or micelles. To confirm that events are induced by single EVs, the MIFlowCyt-EV framework and supporting EV FCM compendium recommend performing assay controls. However, the scientific literature lacks a manuscript that bundles examples and elucidations of the assay controls recommended by the MIFlowCyt-EV framework. Therefore, the goal of this work is to provide the first detailed examples of assay controls, including their purpose, expected outcomes, and control-specific problems and solutions. This manuscript serves as an educational resource regarding assay controls in EV FCM for researchers seeking to measure EVs using FCM.We categorized assay controls into three groups: (1) buffer-only control, (2) controls typical for EV characterization with FCM, including serial-dilution controls, procedural controls, and detergent-treatment controls, and (3) controls assessing staining panel performance, including buffer-with-staining-reagents controls, unstained controls, single-stained controls, isotype controls, positive controls, and negative controls. Test samples, including Dulbecco's phosphate-buffered saline (DPBS), human plasma, human urine, serum, and cell culture supernatant containing EVs were measured with an Apogee A60-Micro flow cytometer. Staining reagents included CD61-PE, CD62p-PE, lactadherin-FITC, IgG1-PE, PKH26 and rVAR2-AF647.In conclusion, assay controls confirm single EV detection by FCM and improve the reliability of EV FCM data. Therefore, assay controls are an essential aspect of EV FCM experiments and their results should always be reported. Moreover, given that certain assay controls can serve multiple EV-characterization techniques, their widespread implementation can enhance the overall reliability of EV data in the field.

Fields of Study & Subjects

Extracellular vesicles in disease Cellular transport and secretion Nanoparticle-Based Drug Delivery

Publication details

Journal / source
Figshare
Publication date
1 January 2026
Language
EN