Active imaging radiometry—not always 1/R2
Summary
No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.
Summarise with VIRAT Free to try with your Science Catalogs account.Abstract
In this paper, we derive general expressions for the signal-to-noise ratio (SNR) of active imaging systems that employ range-dependent illuminator divergence control and receiver zoom configurations. Many practical systems adjust both parameters with range, causing the received focal-plane power to deviate from the standard 1/R^2 dependence used in conventional radiometric calculations. We show that, with an appropriate choice of receiver zoom configuration, the SNR becomes independent of range, aside from range-dependent atmospheric transmission. To illustrate these principles, we analyze a laser-range-gated imaging system that implements illuminator divergence control with two receiver zoom configurations: constant f/# and constant aperture size. We frame the analysis as a radiometric tutorial for both resolved and unresolved targets. Ultimately, we show that the optimal configuration combines range-dependent illuminator divergence control with a constant f/# zoom configuration. These results inform design considerations and performance requirements for active imaging systems.