A method for aerosol fluorescence lifetime measurement based on Mie-fluorescence lidar

Read full text
Authors: Chen Siying, Xian P. Yang, He Chen, Pan Guo, YuRong Jiang, Daoming Li, YangCheng Ma, Haitao Dong, YUHAO JIN, Zhen Yang
Cited by: 0

Abstract

In this Letter, a remote sensing method for measuring the fluorescence lifetime of aerosols is proposed, which combines the Mie-Fluorescence-Lifetime-Scattering (MFLS) model, established based on Mie and fluorescence lidar theory, with the golden section search algorithm. The feasibility of this method was verified through numerical simulations, which demonstrate its ability to measure aerosol fluorescence lifetime by using nanosecond laser pulses. Experimental studies were conducted using a Mie and dual-wavelength fluorescence lidar system on four types of fluorescent substances in aerosol form. The experimental results demonstrate that the proposed method can robustly measure aerosol fluorescence lifetimes on the nanosecond scale, achieving a minimum relative standard deviation of approximately 5.5%. By using fluorescence lifetime as the distinguishing feature, the classification accuracy for four types of fluorescent substances reaches 96.9%. This method offers new opportunities for fluorescence lidar applications in fluorescence lifetime measurement.

Fields of Study & Subjects

Atmospheric aerosols and clouds Advanced Measurement and Detection Methods Advanced Optical Sensing Technologies

Publication details

Journal / source
Figshare
Publication date
1 January 2026