A metallic foreign object detection algorithm in pharmaceuticals based on phase rotation and smoothed pseudo-Wigner-Ville distribution
Summary
No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.
Summarise with VIRAT Free to try with your Science Catalogs account.Abstract
Currently, the pharmaceutical manufacturing industry faces problems such as low accuracy in detecting metal foreign objects due to product effects. To address this issue, this paper proposes a metal detection algorithm based on phase rotation and time-frequency analysis. Phase rotation suppresses product effect interference, and smoothed pseudo-Wigner-Ville distribution (SPWVD) is used to acquire time-frequency images, identifying significant differences representing metal foreign objects and achieving metal detection under strong product effect interference. To ensure computational efficiency meets industrial real-time requirements, an embedded software system with a dual-core CPU and CLA working in tandem is employed, improving algorithm efficiency through hardware improvements. Test results show that the system achieves a detection accuracy exceeding 98% for 0.8 mm ferromagnetic metals and 1.2 mm non-ferromagnetic metals, with a single detection cycle completed within 10 ms.
Fields of Study & Subjects
Non-Destructive Testing Techniques
Machine Fault Diagnosis Techniques
Ultrasonics and Acoustic Wave Propagation
Publication details
- Journal / source
- Progress in Medical Devices
- Volume
- 4
- Issue
- 1
- Pages
- 68–75
- Publication date
- 31 March 2026
- Language