Multidisciplinary endovascular retrieval of a fractured femoral sheath during pulsed field ablation for atrial fibrillation

Read full text Summarise with VIRAT
Authors: Anna Sirignano, Rita Di Rosa, Marco Petrassi, Massimo Messina, Roberto Zinicola, Vincenzo Capasso, Giuseppe Biondi‐Zoccai, Francesco Versaci
Cited by: 0
References: 14

Summary

No summary yet. VIRAT can read this paper and write a plain-language summary of its aim, methods, key findings and limitations.

Summarise with VIRAT Free to try with your Science Catalogs account.

Abstract

Vascular access–related complications remain among the most frequent and clinically significant risks of atrial fibrillation (AF) ablation, despite major advances in imaging guidance and access techniques. Ultrasound-guided femoral puncture has markedly improved safety, yet the need for multiple venous entries, large introducers, and full anticoagulation implies that adverse events, even life-threatening ones, can still occur. We hereby report on a A 69-year-old man with ischemic dilated cardiomyopathy, prior implantable cardioverter-defibrillator (ICD) implantation , who was referred to us for pulsed-field ablation (PFA) due to symptomatic AF refractory to maximal medical therapy, resulting in recurrent inappropriate ICD shocks. While securing dual right ultrasound-guided femoral venous access, a 7-French introducer sheath became kinked and ruptured following mechanical interaction with an advancing SL0 long sheath. Venography confirmed retention of the distal fragment within the right femoral vein. A multidisciplinary team, including an interventional radiologist and a vascular surgeon, was promptly activated, and a conservative endovascular retrieval approach was performed. Via contralateral femoral access, we successfully completed balloon-assisted retrieval, after unsuccessful attempts with a gooseneck snare. Specifically, after advancement of an 8-French Cook sheath via the left femoral vein, a 4-French Berenstein catheter was used together with a 0.035″ guidewire to engage the inner lumen of the sheath. Then, iteratively, the 0.035” was exchanged for a 0.014”, and the Berenstein catheter for a 4.0×30-mm semi-compliant balloon. The latter was delivered inside the sheath fragment, inflated, and used to pull it to the left femoral vein. Indeed, controlled traction enabled safe removal, and final venography demonstrated preserved bilateral venous integrity. The planned PFA was then completed uneventfully through the remaining secure accesses, achieving complete pulmonary vein isolation. On the first postoperative day, a secondary femoral pseudoaneurysm developed, successfully treated surgically. At one-month follow-up, the patient remained in sinus rhythm without arrhythmic events or vascular sequelae. This case demonstrates that rare, high-risk vascular complications can be effectively managed through prompt recognition and multidisciplinary collaborationWhenever possible, an endovascular first approach should be sought as a safe and effective solution.

Fields of Study & Subjects

Vascular Procedures and Complications Atrial Fibrillation Management and Outcomes Central Venous Catheters and Hemodialysis

Publication details

Journal / source
Top Italian Scientists Journal
Volume
3
Issue
2
Publication date
21 March 2026
Language
EN